Assistance 4D probe; recognize the probe by means of the ID code; switch the 4D generate signal via the  electrical relay to generate the 4D probe operate Typically. 4.2.2 Principal board The key board can be divided into two areas: entrance-conclude of the leading board and again-end of the key board.

Written content Process Check the battery periodically : a) Check if battery may be billed Generally when electricity-on: That the current potential is one hundred% or capacity boosts right after a brief time signifies which the battery may be billed Usually.

Analyzing clients in nowadays’s demanding environment requires ground breaking technological know-how that permits clinicians to produce fast and self-assured diagnoses. The versatility on the DP-50 expands your clinical utility even though assisting to strengthen client treatment.

The user is not really allowed to open the addresses and panel of your method, neither Observe: unit disassemble is permitted. To make sure the method performance and safety, only Mindray engineers or engineers authorized by Mindray can conduct maintenance.

Explore much better diagnostic information and facts as a result of prolonged see of your anatomical composition on all convex probes.

Cut off cable ties connecting the principle device over the display by diagonal cutting pliers, and afterwards pull out the corresponding cable plugs.

Essential information about our romance along with you: Consumer Relationship Summaries Our Consumer Romance Summaries give you a short summary of our companies, fees and obligations after we perform with you within a broker-supplier or an financial investment advisory romantic relationship.

Mindray’s new era of black & white ultrasound system, DP-fifty Qualified, is supplied with Sophisticated imaging systems letting deeper penetration and more quickly graphic acquisition with increased resolution.

Perform: To the back again-conclude of the main board, a Exclusive check IC is made use of to monitor sign voltages  and clock battery electric power which might be provided to the principle board by the key device box energy source module.

The chapter provides the method to verify main function and efficiency of item. This can be only utilized for reference, not preventive execution. Perform examining and testing of this aspect shall be performed by Mindray services engineers plus the user together. Website page 66: General Exam

Cookies are essential to the right functioning of a internet site. To boost your experience, we use cookies to recollect log-in facts and supply protected log-in, accumulate statistics to optimize web site performance, and supply written content tailored for your interests.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Immediately after changing the CPU module, key file needs to be generated Again according to the new MAC tackle and created into HDD of your machine. Or else, the configuration purpose of the merchandise will probably be missing. Following taking away the CPU module, Remove panhead screws with washers (12 M3X6) mounted on the main unit box, you will take from the board. Site 118 Determine eight-29 Disassemble the Control Panel Assembly (1) Hold the upper edge of user interface assembly, and open up the control panel. Figure 8-30 Disassemble the Control Panel Assembly (two) Just after eradicating just one countersunk head self-tapping screw PT3X10 mounted around the control panel and take Dp50rb out the plug from the keyboard and the primary device connecting cables, you could remove the user interface assembly.

Not all services and products mentioned are available outside the U.S. and a few are topic to nation precise restrictions.

Mindray respects your privacy. We use cookies for a variety of reasons, such as Web site functionality, improving your working experience of our Internet site, making integration with social media and assisting focus on our promoting.

five.two.three Geometric positioning accuracy Longitudinal geometric positioning accuracy  Test Move: Do changes as just how in testing the utmost depth. Report the gap by 20mm Each individual section on the longitudinal targets line using the measurement caliper; Select the worth with the greatest mistake (to 20mm), work out the precision utilizing the method below The measurement caliper really should be positioned with the upper edge of the focus on, Observe:... Page 79 Transverse geometric positioning accuracy  Examination Phase: Go over the scan surface area of the phantom with water or couple gel, Carefully Get in touch with the probe Along with the scan floor Alter the depth, earning the transverse targets to be exhibited inside the graphic. Adjust the focus point to generally be posited beside the transverse targets (the regular is not distinct) Change parameters like acquire, TGC, earning Each individual transverse targets to get Plainly shown. Web site eighty five.5.2.four Blackout Region Examination Phase: Address the scan area with the phantom with drinking water or couple gel, Carefully contact the probe Together with the scan surface area Alter the depth at a lower benefit, and set the focus at the closest location to the scan surface area. Decrease the worth of parameters like AP, Achieve right up until the track record sounds just is usually noticed. Site 81: Software program Up grade And Maintenance